home *** CD-ROM | disk | FTP | other *** search
/ Software Vault: The Diamond Collection / The Diamond Collection (Software Vault)(Digital Impact).ISO / cdr22 / neondet.zip / NEONDET.ASC < prev    next >
Text File  |  1995-02-04  |  3KB  |  67 lines

  1.  
  2.  
  3.  
  4.  
  5.                 (word processor parameters LM=8, RM=75, TM=2, BM=2)
  6.                       Taken from KeelyNet BBS (214) 324-3501
  7.                            Sponsored by Vangard Sciences
  8.                                     PO BOX 1031
  9.                                 Mesquite, TX 75150
  10.  
  11.                        There are ABSOLUTELY NO RESTRICTIONS
  12.                   on duplicating, publishing or distributing the
  13.                        files on KeelyNet except where noted!
  14.  
  15.                                   January 16,1994
  16.  
  17.                                     NEONDET.ASC
  18.        --------------------------------------------------------------------
  19.              This file shared with KeelyNet courtesy of Joel McClain.
  20.               Also take the diagram NEONDET.GIF, see also MAGALT.ZIP.
  21.        --------------------------------------------------------------------
  22.        The schematic, NEONDET.GIF,  is a derivative of a microwave detector
  23.        described in the  February,  1980,   "Ham   Radio"   magazine.    As
  24.        originally created, the circuit's purpose is to detect  microwave RF
  25.        standing waves, but  with minor modification, it can also be used as
  26.        an effective scalar wave detector.
  27.  
  28.        The schematic shows a round magnet epoxied to the NE-2 lamp, to help
  29.        isolate it from EM signals.  Additionally,  the  circuit  should  be
  30.        enclosed in a  metal  box,  or  "Faraday  Cage", with  shielded  I/O
  31.        connectors.
  32.  
  33.        The power source  consists  of  eight 9V batteries.  Battery life is
  34.        very nearly the same as shelf life,  because the lamp is operated in
  35.        "starvation" mode, drawing approximately 0.1ma.
  36.  
  37.        The 25K and 250K potentiometers are adjusted first to fire the NE-2,
  38.        at approximately 60-70 volts, then adjusted until  only  the  tip of
  39.        the cathode electrode  glows.   The 100K pot is adjusted for optimum
  40.        output gain.
  41.  
  42.        Notes:
  43.  
  44.            1.  The 741 can be replaced with  a  1458  cascade amplifier for
  45.                better results.
  46.            2.  The  RF  loops  in  the NE-2 leads are mandatory  to  reduce
  47.                interference as well as lamp current noise.
  48.            3.  Component  values  are  not  critical, and can be changed as
  49.                required for the type of output device.
  50.            4.  Removing  the  magnet  and   Faraday   Cage,  and  adding  a
  51.                capacitively coupled  loop  antenna  will permit  use  as  a
  52.                microwave EM detector.
  53.        --------------------------------------------------------------------
  54.          If you  have comments or other information relating to such topics
  55.          as  this paper covers,  please   upload to KeelyNet or send to the
  56.            Vangard  Sciences  address  as  listed  on the  first  page.
  57.               Thank you for your consideration, interest and support.
  58.            Jerry W. Decker.........Ron Barker...........Chuck Henderson
  59.                              Vangard Sciences/KeelyNet
  60.        --------------------------------------------------------------------
  61.                      If we can be of service, you may contact
  62.                  Jerry at (214) 324-8741 or Ron at (214) 242-9346
  63.        --------------------------------------------------------------------
  64.  